Product Specifications:

ItemCircuit Breaker
AC Voltage Rating600 VAC
ActuatorToggle
Amps350
Circuit Breaker TypeStandard
Current Rating350A
DC Voltage Rating250 VDC
Depth5.84"
Frame Size400A/LA
Height11"
High Amp Trip Setting3500A
Instantaneous TripAdjustable
Low Amp Trip Setting1750A
Magnetic Hold Current1750A
Magnetic Tripping Current3500A
Max. AIR RatingNot Rated
Max. Wire Size600 kcmil (Al), 250 kcmil (Al)
Min. Wire Size1 AWG (Al)
MountingFree Standing
Mounting StyleUnit Mount
Number of Poles3
Phase3
Phase ConnectionABC
Terminal ConnectionLug
Trip TypeThermal Magnetic
Voltage Rating600V AC, 250V DC
Width6"
Wire Size250 MCM, 600 MCM

Shipping Info:

Ship weight (kg) 7.29
Ship height (cm)23.62
Ship length (cm)44.2
Ship width (cm)29.46
HS code8536200040

Product Details:

Square D LAL36350 pressure switch is used to monitor and control pressure levels within equipment or systems. It accurately detects pressure changes for optimal operation, preventing overpressure and safeguarding equipment. This pressure switch is utilised in manufacturing, automation and HVAC applications to maintain desired pressure ranges.

Working Mechanism:

  • When the pressure surpasses a predetermined threshold, the pressure switch's mechanism is activated.
  • The switch's diaphragm actuation mechanism reacts to changes in pressure, triggering further action.
  • As the diaphragm moves, the SPDT contact configuration switches position.
  • This contact position change either opens or closes an electrical circuit.
  • The alteration in the circuit's state prompts the system to respond accordingly. For instance, it might initiate equipment shutdown or activate warning alarms.
  • When pressure returns to an acceptable range, the pressure switch resets itself.
  • With the reset, the pressure switch reinstates the electrical circuit, allowing the system to resume its normal operation.

Features:

  • It features an adjustable instantaneous trip for precise customisation of circuit protection thresholds.
  • This pressure switch has 3-pole, 3-phase and thermal-magnetic trip protection for enhanced safety from electric hazards.
  • It comes with line & load lug terminals for easy connection.
  • This Square D circuit breaker has a current rating of 350A, voltage rating of 600VAC / 250 VDC and a maximum interrupt current rating of 42kA at 240VAC.

Frequently Asked Questions:

Q. How do I clean and maintain Square D LAL36350 pressure switch?

A.

  • Turn off power to ensure safety during maintenance.
  • Perform visual checks for dirt, debris and corrosion.
  • Use a soft cloth to gently wipe down the switch.
  • Use compressed air to remove dust from hard-to-reach areas.
  • Inspect and tighten terminals if needed.
  • Test the switch's functionality periodically.
  • Verify and adjust setpoints if required.

Q. How do I install this pressure switch?

A.

  • Prioritise safety by turning off the power supply before beginning installation.
  • Confirm pressure switch suitability and compatibility with your application's requirements.
  • Disconnect power to ensure a safe working environment.
  • If replacing an old switch, disconnect and remove it.
  • Follow the manufacturer's wiring diagram to connect power source and load wires to the pressure switch terminals.
  • Attach the pressure line from your system to the pressure port on the pressure switch.
  • Securely mount the pressure switch in a stable location using appropriate hardware.
  • Adjust pressure switch settings like cut-in and cut-out pressures according to your system's needs.
  • Test the pressure switch's functionality after ensuring all connections are secure.
  • Seal access panels, insulate connections and restore power to complete the installation process.

Q. What factors should I consider while choosing a pressure switch?

A.

  • Ensure compatibility with your system's pressure requirements.
  • Match voltage, current and type to your system.
  • Opt for flexibility with adjustable setpoints.
  • Consider precision and hysteresis to prevent frequent cycling.
  • Verify suitable protection and placement for your setting.

Documentation:

Product Variants

ProductModelAmpsDepthPrice
SQUARE D LAL36250 Circuit Breaker 250a 3p 600vac Lug | AG7CXD 5B915
LAL362502505.8"A$7,123.28
SQUARE D LAL36300 Circuit Breaker, 300 A, 600 VAC, 30 kAIC @ 480 VAC | AG7CXE 5B916
LAL363003005.8"A$7,123.28
SQUARE D LAL36400 Molded Case Circuit Breaker, LAL, 400 A, 600 VAC, Lug, 3 P | AG7CXG 5B918
LAL364004005.8"A$7,123.28

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 09:00 until 17:00.

SQUARE D LAL36350 Circuit Breaker, 350A, 3 Pole, 600VAC, Lug
A$7,123.28 /unit (inc. GST)