Flat Shipping

Flat Rate Shipping at AUD 29.99 + GST

*T&C Apply

ROBINAIR RG3 Refrigerant Recovery Machine, 115V, NEMA 5-15p Male Plug | AG6RMQ 46C629

ROBINAIR RG3 Refrigerant Recovery Machine, 115V, NEMA 5-15p Male Plug

Item: AG6RMQ Model: RG3Cross Ref: 46C629
In Stock
Shipping to

Get it by May 3, Friday

Flat Rate Shipping at 29.99 + GST AUD 29.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.

A$1,896.73 /unit (inc. GST)
Add To Cart
Request a Quote

Payment Methods

Delivery Partners

Product Specifications:

ItemRefrigerant Recovery Machine
Depth8.3"
Electrical ConnectionsIEC Connector and Power Cord
Height11"
Hose Connection1/4" or larger
Motor HP1/3
RequiresHoses, Recovery Cylinder, Manifold Gauge Set, Hoses
Type2-Port
UPC637335043374
Voltage115
Width568582"

Shipping Info:

Ship weight (kg) 9.89
Ship height (cm)27.94
Ship length (cm)20.96
Ship width (cm)38.1
HS code2710193080

Product Details:

Robinair RG3 refrigerant recovery machine is used to recover both liquid & vapour refrigerants from systems before servicing them. This refrigerant recovery unit can recover CFC, HFC & HCFC refrigerants and store them in a 30 / 50-lb DOT-approved cylinder. It comes with compatible hoses, a manifold gauge set & a recovery cylinder.

Working Mechanism:

  • After properly setting up the unit, follow the standard operating procedures.
  • Connect the machine to a 115V power supply and open the cylinder's liquid valve slowly to check for leaks.
  • Open manifold gauge set's liquid valve and the outlet valve on the unit.
  • Switch On the unit and open the unit's inlet valve slowly.
  • Remove the liquid refrigerant fully.
  • Now open the manifold gauge set's vapour valve to evacuate the system till the required vacuum condition is achieved.
  • Close the valves on the manifold & the unit before switching off the unit.

Features:

  • Robinair RG3 refrigerant recovery machine is a compact & lightweight unit with an oilless compressor & simple 2-valve controls for easy vapour and liquid refrigerant recovery.
  • It is equipped with a safety switch to shut down the unit automatically when the pressure goes beyond 550 psi.
  • The unit comes with a filter screen placed behind the inlet fitting. Users should clean the screen after every use.
  • It is equipped with a NEMA 5-15p male plug for supplying 115V power to the 1/3 hp motor.
  • The unit has 1/4 inch male connections for secure fitting of hoses.
  • It has a fan and condenser for maximising efficiency with shorter cycle times.
  • The unit features 2 easy to read gauges for checking the refrigerant pressures quickly and a comfortable handle to carry the unit to the desired location.
  • It comes with an instruction manual for referring to correct procedures & steps of refrigerant recovery.

Compatible Accessories:

  • Robinair 100343 Filter / Dryer: Users can install these filter / dryer units at the inlet fitting for removing contaminants / moisture from the incoming refrigerants in the system being serviced.

Standards and Approvals:

  • UL (ARI-740)
  • CE

Frequently Asked Questions:

Q. How to set up this Robinair RG3 refrigerant recovery machine?

A.

  • Firstly, place the machine on a stable surface.
  • Install a clean filter screen or filter / dryer to the inlet fitting.
  • Connect a hose from the liquid port of the recovery cylinder into the outlet fitting on the unit.
  • Connect a hose from the outlet port of a manifold gauge set to the inlet fitting on the unit through the filter / dryer.
  • Connect a hose from the selected system's liquid side to the liquid (low pressure) side of the manifold gauge set.
  • Connect a hose from the system's vapour side to the vapour (high) side of the manifold gauge set.
  • Close all the inlet & outlet valves and place the cylinder on a weighing scale to prevent its overfilling.

Q. What type of cylinders are required for use with this Robinair RG3 refrigerant recovery machine?

A.

  • The selected cylinder should be an authorised, refillable refrigerant storage cylinder specs.
  • Robinair recommends using 400 psi (27.6 bar) cylinders or at least a 350 psi (24.1 bar) cylinder.
  • Closed cylinders should be filled up to 80% of their volume to prevent personal injury & equipment damage.
  • Recovery cylinders & filter / dryers should be used with only one refrigerant type.
  • Refrigerant cylinders should be stored in a cool, dry place.

Q. What is the push / pull procedure in this recovery machine?

A. Push / pull procedure in this Robinair RG3 refrigerant recovery machine is used to recover refrigerants from large systems containing bulk liquids over 15 lb. Users should follow the push / pull method as described in the unit's instruction manual.

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 09:00 until 17:00.

ROBINAIR RG3 Refrigerant Recovery Machine, 115V, NEMA 5-15p Male Plug
A$1,896.73 /unit (inc. GST)