Product Specifications:

ItemPower Supply 8PTC 12 VDC Or 24 VDC @ 6A
Batteries RequiredNo
Enclosure Depth (In.)4.50
Enclosure Height (In.)15.5
Enclosure Width (In.)12.00
FinishGrey
Input Frequency60 Hz
Input Voltage115 VAC
MaterialSteel
Number of Outputs12 VDC or 24 VDC
Output Current6A
Sub-CategoryPower Supply/Charger
TypeAccess Power Controller
Voltage Output12 VDC or 24 VDC

Shipping Info:

Ship weight (kg) 4.94
Ship height (cm)34.29
Ship length (cm)41.66
Ship width (cm)14.99
HS code8537109070
Country of OriginUS

Product Details:

Altronix AL600ULACMCB access power controller with a power supply provides reliable and uninterrupted power to access control equipment, including card readers, electronic locks, and surveillance cameras. It ensures that these critical components remain operational, safeguarding premises and enhancing security. This power controller is used in commercial buildings, educational institutions, healthcare facilities and industrial complexes.

Working Mechanism:

  • The controller typically receives input power from a primary power source, which can either be a shared power source for both board operation and locking devices or two distinct power sources.
  • The controller is equipped with multiple outputs that offer independent control for various access control components.
  • Activation of these outputs is achieved through an open collector sink or a normally open (NO) dry trigger mechanism.
  • When one of these access control components triggers an input signal, the controller promptly responds by supplying power to the corresponding output, thus enabling or disabling access control hardware devices.
  • The controller provides the flexibility to individually select the fire alarm disconnect feature for any or all of its eight outputs, offering customized control over emergency response scenarios.

Features:

  • It allows output activation through an open collector sink or normally open (NO) dry trigger input from various access control system components like card reader, keypad, pushbutton and PIR.
  • This power controller can route power to Mag Locks, electric strikes and magnetic door holders.
  • It offers the flexibility of operating in both Fail-Safe and Fail-Secure modes for enhanced security control.
  • This unit allows individual selection of the fire alarm disconnect feature for any or all of its eight (8) outputs, offering precise control and customisation.
  • It is equipped with the option for a single common power source (factory installed) to supply power for both board operation and locking devices or the alternative of two independent power sources, one for board operation and another for lock/accessory power.
  • This FACP interface enables emergency egress, alarm monitoring and the triggering of auxiliary devices, serving diverse security needs.

Frequently Asked Questions:

Q. What maintenance is required for Altronix AL600ULACMCB access power controller?

A.

  • Output Voltage Test: Examine the DC output voltage under standard load conditions to verify its adherence to the specified voltage levels.
  • Battery Test: Confirm the battery's full charge status under normal load conditions and assess the specified voltage at both the battery terminals and the board terminals marked as [+ BAT ?], ensuring the absence of any interruptions in the battery connection wires.

Q. How to install this access power controller?

A.

  • Mark and predrill holes in the wall, aligning them with the top two keyholes on the enclosure.
  • Securely install two upper fasteners and screws into the wall, ensuring that the screw heads protrude.
  • Position the enclosure's upper keyholes over the two upper screws, making sure it's level and then secure it in place.
  • Mark the location for the lower two holes.
  • Remove the enclosure and proceed to drill the lower holes.
  • Install three fasteners into the newly drilled holes.
  • Place the enclosure's upper keyholes over the two upper screws again.
  • Install the two lower screws and be sure to tighten all screws securely.

Q. What is the operating temperature of Altronix AL600ULACMCB access power controller?

A. It has operating temperatures ranging from 0 to 49 degrees C.

Product Variants

ProductModelItemNumber of OutputsOutput CurrentVoltage OutputPrice
ALTRONIX AL1012ULACM Power Supply 8 Fuse 12vdc | AD9KHP 4TEF8
AL1012ULACMPower Supply 8Fuse 12 VDC @ 10A12 VDC10A12 VDCA$1,099.96
ALTRONIX AL1024ULACM Access Power Controller w/ Power Supply, 60 Hz, Gray Finish | AD9KJB 4TEH1
AL1024ULACMPower Supply 8 Fuse 24 VDC @ 10A24 VDC10A24 VDCA$1,268.08
ALTRONIX AL400ULACM Access Power Controller w/ Power Supply, 60 Hz Input | AD9KKX 4TEN7
AL400ULACMPower Supply 8Fuse 12Dc/3.5A Or 24Dc/3A12 VDC or 24 VDC12 VDC @ 4A or 24 VDC @ 3A12 VDC or 24 VDCA$952.31
ALTRONIX AL400ULACMCB Wall Mount Access Power Controller w/ Power Supply, 8 PTC | AD9KKY 4TEN8
AL400ULACMCBPower Supply 8PTC 12Dc/3.5A Or 24Dc/3A12 VDC or 24 VDC12 VDC @ 4A or 24 VDC @ 3A12 VDC or 24 VDCA$804.19
ALTRONIX AL600ULACM Access Power Controller w/ Power Supply, 60 Hz, Cam Lock | AD9KLP 4TER6
AL600ULACMPower Supply 8Fuse 12 VDC Or 24 VDC @ 6A12 VDC or 24 VDC6A12 VDC or 24 VDCA$1,086.34

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 09:00 until 17:00.

ALTRONIX AL600ULACMCB Access Power Controller w/ Power Supply, 12/24VDC @ 6A
A$1,118.17 /unit (inc. GST)