EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers

Eaton xEffect FRCmM-NA residual current circuit breakers (RCCBs) are ideal for sensing and disconnecting any low voltage (uneven current) circuit whenever a fault occurs. They are used in offices, industrial layouts and low-voltage applications.

Filter
StyleModelPrice (inc. GST)
A
167102
-A$ 4,051.76
RFQ
B
167701
-A$ 4,051.76
RFQ
C
167698
-A$ 2,364.24
RFQ
B
167125
-A$ 4,051.76
RFQ
B
167699
-A$ 4,051.76
RFQ
D
167693
-A$ 2,030.19
RFQ
E
167695
-A$ 2,030.19
RFQ
B
167709
-A$ 4,385.81
RFQ
C
167696
-A$ 2,364.24
RFQ
C
167697
-A$ 2,364.24
RFQ
C
167124
-A$ 2,364.24
RFQ
B
167700
-A$ 4,051.76
RFQ
B
167710
-A$ 4,385.81
RFQ
B
167703
-A$ 4,385.81
RFQ
B
167704
-A$ 4,385.81
RFQ
B
167705
-A$ 4,051.76
RFQ
B
167707
-A$ 4,051.76
RFQ
B
167702
-A$ 4,385.81
RFQ
B
167708
-A$ 4,385.81
RFQ
F
167694
-A$ 2,030.19
RFQ
G
167120
-A$ 2,030.19
RFQ
B
167110
-A$ 4,385.81
RFQ
C
167116
-A$ 2,364.24
RFQ
B
167104
-A$ 4,385.81
RFQ
B
167106
-A$ 4,385.81
RFQ
H
167103
-A$ 4,051.76
RFQ
B
167111
-A$ 4,385.81
RFQ
I
167107
-A$ 4,051.76
RFQ
J
167109
-A$ 4,051.76
RFQ
C
167114
-A$ 2,030.19
RFQ
K
167115
-A$ 2,030.19
RFQ
C
167122
-A$ 2,364.24
RFQ
C
167117
-A$ 2,364.24
RFQ
C
167123
-A$ 2,364.24
RFQ
B
167112
-A$ 4,385.81
RFQ
C
167113
-A$ 2,030.19
RFQ
C
167118
-A$ 2,364.24
RFQ
L
167108
-A$ 4,051.76
RFQ
M
167121
-A$ 2,030.19
RFQ
N
167119
-A$ 2,030.19
RFQ
B
167706
-A$ 4,051.76
RFQ

Working Mechanism

  • During an earth fault, the residual current circuit breaker continuously detects and contrasts any differences in the current between the live and neutral wires (residual current value).
  • The residual current circuit breaker will trip if there is even a slight difference in the numbers, cutting off the circuit.

Features

  • Eaton xEffect FRCmM-NA RCCBs feature Type A and Type G/A capable of sensing residual pulsating DC offering surge current-proof of 250A and 3kA respectively.
  • They come with a unique test button 'T' to automatically test the function of residual current circuit breakers (RCCB) themselves.
  • These RCCBs devices further feature independent line voltage tripping and operation temperature range of -25 to 40 degrees C.
  • They offer delayed tripping suitable with conventional fluorescent tubes, irrespective of whether electronic ballast is present or not.
  • These circuit breakers provide a tripping indicator and a contact position indicator for additional safety.

Standards and Approvals

  • IEC
  • EN 61008
  • UL

Frequently Asked Questions

What is the rated short circuit capacity of Eaton xEffect FRCmM-NA RCCBs?

5kA (according to CSA)

What is the rated tripping current of these residual current breakers?

30 / 300mA

How do we connect an FRCmM-NA residual current device?

  • RCCB is connected parallel to the miniature circuit breaker (MCB) into the distribution boards.