EATON CH Series Standard Circuit Breakers

Eaton CH Series standard circuit breakers are installed in CH-type loadcenters for preventing electrical damage to connected devices due to excess current or short circuits. They have a plug-on type ...Read More

Filter
AIC Rating: 42kAIC@240V , Frame Type: CHH , Number of Poles: 2
StyleModelAmpsVoltagePrice (inc. GST)
A
CH290ST
---
RFQ
B
CH320SW
--A$ 245.28
RFQ
C
CH3080ST
--A$ 1,130.72
D
CH3080
---
RFQ
C
CH3090ST
--A$ 1,130.72
D
CH3090
--A$ 540.42
E
CH310
--A$ 317.96
C
CH3100ST
---
RFQ
F
CH3100
--A$ 560.71
G
CH315HID
--A$ 952.72
RFQ
B
CH315SW
--A$ 338.95
C
CH320ST
--A$ 917.41
H
CH315
---
RFQ
C
CH315ST
---
RFQ
I
CH320
--A$ 296.71
J
CH320SWST
--A$ 733.74
RFQ
K
CH325
--A$ 311.27
L
CH120
--A$ 33.41
RFQ
C
CH330ST
--A$ 917.41
G
CH330HID
--A$ 952.72
RFQ
M
CH345
---
RFQ
C
CH350ST
---
RFQ
B
CH340SW
--A$ 305.33
RFQ
C
CH340ST
--A$ 917.41
N
CH350
--A$ 306.34
O
CH330
--A$ 296.71
P
CH335
---
RFQ
Q
CH340
--A$ 306.34
R
CH360
--A$ 306.34
C
CH345ST
--A$ 890.59
RFQ
J
CH350SWST
--A$ 722.16
RFQ
S
CH370
--A$ 490.44
T
CH280
--A$ 244.27
U
CH270
--A$ 232.30
C
CH360ST
--A$ 917.41
V
CH290
--A$ 311.59
RFQ
W
CH160
---
RFQ
X
CH160ST
--A$ 449.50
RFQ
Y
CH170
--A$ 111.62
RFQ
X
CH170ST
--A$ 509.52
RFQ
Z
CH2100CS
--A$ 316.87
RFQ
A1
CH2100X
---
RFQ
B1
CH2125
--A$ 647.44
RFQ
C1
CH2100
--A$ 232.30
A
CH2100ST
---
RFQ
D1
CH2100N
--A$ 354.78
RFQ
E1
CH2110CS
--A$ 660.03
RFQ
D1
CH2125N
--A$ 824.27
RFQ
A1
CH2125X
--A$ 761.71
A1
CH2150X
---
RFQ
F1
CH2125CS
--A$ 660.03
RFQ
A
CH2125ST
---
RFQ
G1
CH260
--A$ 167.88
A
CH270ST
---
RFQ
A
CH280ST
---
RFQ
H1
CH270M50
--A$ 269.52
RFQ
A
CH260ST
---
RFQ
H1
CH250M50
--A$ 113.73
RFQ
I1
CH260CS
--A$ 148.48
RFQ
J1
CH2110
--A$ 560.71
K1
CH230SWST
--A$ 642.16
RFQ
12

Features

  • Eaton CH Series circuit breakers have a sliding handle with ON & OFF indication positions for easy identification of the breaker's status.
  • They have 1 / 2 / 3-poles for application-specific performance.
  • Their thermal-magnetic trip mechanism prevents nuisance tripping due to mild overloads while acting almost instantaneously during severe short-circuit conditions.
  • Eaton CH Series circuit breakers having more than one pole are equipped with an internal common trip connection for simultaneous operation of the poles.
  • They have a quick-make & quick-break switch mechanism for safe & efficient operation.
  • These circuit breakers require 3/4-inch (19.1 mm) space per pole for installation.
  • Selected models have a clamshell pack for enhanced durability, an MCB kit for easy installation on MCBs and a shunt trip for tripping the breakers remotely at any time.

Compatible Accessories

  • Eaton CHHT Handle Tie Bar: This handle tie bar with a moulded plastic handle cover can physically join the handles of adjacent CH type circuit breakers having a single pole.
  • Eaton CHPL Handle Lockoff: This is a padlockable device that locks the handle of escutcheon-mounted CH-type circuit breakers.
  • Eaton CHML Mechanical Interlock: It secures & locks 2, 3 & 4-pole CH type breakers.

Standards and Approvals

  • UL 489

Frequently Asked Questions

What is the voltage rating of these Eaton CH Series circuit breakers?

Eaton CH Series circuit breakers have a voltage rating of 120 / 240V and an interrupt rating of 10kAIC.

What are the points to inspect before operating these Eaton CH Series circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.

What wire gauges are suitable for wiring these Eaton CH Series circuit breakers?

  • #10-1/0 AWG
  • #14-2 AWG
  • #14-8 AWG

We are here to help!

Looking for a part not listed here?