EATON BR Series Thermal Magnetic Circuit Breakers

Eaton BR Series thermal magnetic circuit breakers combine thermal and magnetic elements to provide overcurrent protection in residential and commercial applications.

Filter
AIC Rating: 10kAIC@240V , Frame Type: BR
StyleModelAmpsNumber of PolesVoltagePrice (inc. GST)
A
BR235H
---A$ 64.03
RFQ
B
BR290
---A$ 151.34
C
BR3100B
---A$ 555.81
RFQ
D
BR3050
---A$ 148.48
RFQ
D
BR3030
---A$ 66.39
D
BR3020
---A$ 66.39
E
BR290CS
---A$ 183.46
RFQ
A
BR290H
---A$ 217.04
RFQ
F
BR280ST
----
RFQ
G
BR290BP50
---A$ 188.25
RFQ
H
BR315ST
----
RFQ
I
BR270B
---A$ 154.21
RFQ
A
BR280H
---A$ 217.04
RFQ
A
BR270H
---A$ 154.21
RFQ
J
BR280
---A$ 151.34
K
BR270CS
---A$ 132.46
RFQ
I
BR270
---A$ 123.76
L
BR280BP50
---A$ 188.25
RFQ
M
BR3100
---A$ 361.01
N
BR310
---A$ 428.49
RFQ
O
BR270BP50
---A$ 132.00
RFQ
P
BR330
---A$ 209.42
C
BR370B
---A$ 320.32
RFQ
Q
BR360
---A$ 209.42
R
BR370
---A$ 307.15
C
BR350B
---A$ 262.45
RFQ
H
BR350ST
----
RFQ
S
BR345
---A$ 213.99
H
BR370ST
----
RFQ
T
BR360NA
---A$ 318.98
RFQ
H
BR3100ST
----
RFQ
U
BR335
---A$ 213.99
V
BR325
---A$ 209.42
W
BR340
---A$ 209.42
H
BR330ST
----
RFQ
H
BR320ST
---A$ 503.92
X
BR315
---A$ 209.42
Y
BR320
---A$ 209.42
C
BR260B
---A$ 79.62
RFQ
F
BR260ST
----
RFQ
H
BR340ST
---A$ 503.92
Z
BR225BP50
---A$ 55.65
RFQ
A1
BR235
---A$ 55.95
A
BR230H
---A$ 67.17
RFQ
A
BR225H
---A$ 64.03
RFQ
F
BR230ST
----
RFQ
B1
BR225
---A$ 51.37
C1
BR230BP50
---A$ 54.42
RFQ
D1
BR230
---A$ 51.37
F
BR225ST
---A$ 302.90
RFQ
E1
BRHH220
---A$ 632.23
RFQ
A
BR215H
---A$ 67.17
RFQ
F1
BR220
---A$ 70.93
C
BR220B
---A$ 67.79
RFQ
C
BR230B
---A$ 67.79
RFQ
G1
BR2135CS
---A$ 68.43
RFQ
A
BR220H
---A$ 67.17
RFQ
F
BR220ST
---A$ 307.15
F
BR235ST
---A$ 286.74
RFQ
F
BR240ST
---A$ 307.15
H1
BR260
---A$ 55.95
12...67

Working Mechanism

  • Eaton thermal magnetic circuit breakers consist of a bimetallic strip that responds to heat caused by excessive current flow and a solenoid-actuated plunger that responds to strong magnetic fields generated by high currents.
  • When the current flowing through the circuit exceeds the rated capacity of the breaker, the bimetallic strip heats up and causes the breaker to trip.
  • The magnetic element trips the breaker if it detects high magnetic fields.
  • By stopping the flow of current when the breaker trips, it safeguards the circuit from damage.

Features

  • Eaton BR Series thermal magnetic circuit breakers have a short-body design that allows the addition of more wire-way and gutter space in the loadcenter.
  • Their improved diagnostic trip codes are designed for complex occurrences and overload to provide easy troubleshooting during maintenance.
  • These circuit breakers have easy-to-read trip codes through improved LEDs and a clear test button for efficient troubleshooting.

Standards and Approvals

  • UL
  • CSA

Frequently Asked Questions

Can a thermal magnetic circuit breaker be reset after it has tripped?

Yes, Eaton thermal magnetic circuit breakers can be reset after they have tripped. To reset the breaker, locate the breaker's handle and move it to the Off position. Then, move the handle back to the On position to reset the breaker.

How to avoid unnecessary tripping of breakers?

Circuit breakers trip unnecessarily only when they are dirty. Keep the circuit breakers clean and free of dirt or debris to avoid unnecessary tripping.

What is the difference between a circuit breaker and a fuse?

A circuit breaker has an internal switch that trips when there is excess current, whereas a fuse is a metal piece that melts when excess current overloads the circuit.

We are here to help!

Looking for a part not listed here?