Body Dia.: 5.625" , Bolt Circle Dia.: 5.125" , Duty: Continuous Air-Over , Hz: 60 , Insulation Class: B , Motor Application: H VAC/R , Motor Design: Permanent Split Capacitor , Motor Sub Application: Condenser Fan , Motor Thermal Protection: Auto , Motor Type: PSC , Phase: 1 , Rotation: CW/CCW , Service Factor: 1.0 , Shaft Dia.: 1/2" , Thermal Protection: Auto
StyleModelLength Less ShaftBearingsCapacitor RequiredMax. Ambient Temp.Motor Enclosure DesignMotor Mounting PositionMotor Shaft DesignMountingPrice (inc. GST)
A
4M261
4 7/16"Ball2MDV260 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 235.73
A
3M839
4 11/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 368.68
B
4M225
4 11/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 375.43
C
4M223
4 11/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 339.13
D
4M205
4 11/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 233.66
E
4M060
4 11/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 489.52
F
4M226
4 15/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 419.36
G
4M224
4.875"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 375.43
A
3LU93
5 3/16"Ball2MDV460 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 380.58
A
4M206
5 3/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 275.44
H
3LU94
5 3/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 380.75
I
4M061
5 3/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 431.20
J
4M207
5 7/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 280.92
K
3LU96
5 7/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 404.27
L
3M265
5 11/16"SleeveIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 415.78
M
3M990
5 11/16"SleeveIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 462.86
N
4M262
5 11/16"Ball2MDV760 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 522.41
O
3M217
5 11/16"BallIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 417.23
P
3LU95
5 11/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 404.45
A
4M062
5 15/16"Ball2MDV760 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 646.71
Q
3LU98
5 15/16"Ball2MDV760 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 429.90
A
3LU97
5 15/16"Ball2MDV660 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 516.74
R
5RHU4
5.25"Ball2MDV6, 2MDV770 Degrees CTotally Enclosed Air-OverAll AngleFlatStud/BandA$ 437.62
R
5RHU6
5.75"BallIncluded70 Degrees CTotally Enclosed Air-OverAll AngleFlatStud/BandA$ 569.07
R
5RHU3
5.625"Ball2MDV6, 2MDV770 Degrees CTotally Enclosed Air-OverAll AngleFlatStud/BandA$ 523.36
S
5RHU2
5.625"Ball2MDV770 Degrees CTotally Enclosed Air-OverAll AngleFlatStud/BandA$ 395.80
A
4M263
6 7/16"Ball2MDV860 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 549.25
T
3LU99
6 7/16"Ball2MDV760 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 511.13
U
3M769
6 7/16"Ball2MDV960 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 493.75
V
4M208
6 7/16"Ball2MDV760 Degrees CTotally Enclosed Air-OverAll AngleDouble-FlatStudA$ 377.45
W
3M221
6 15/16"SleeveIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 598.33
X
3M224
6 15/16"BallIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 533.76
Y
3M226
6 15/16"SleeveIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 417.21
Z
3M994
6 15/16"BallIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 702.11
R
5RHU7
6"BallIncluded70 Degrees CTotally Enclosed Air-OverAll AngleFlatStud/BandA$ 433.40
R
5RHU5
6"Ball2MDV6, 2MDV770 Degrees CTotally Enclosed Air-OverAll AngleFlatStud/BandA$ 496.25
A1
3M295
7.437"BallIncluded60 Degrees COpen Air-OverHorizontal or Vertical Shaft UpDouble-FlatCradleA$ 481.03

Condenser Fan Motors, 1/2 Inch Shaft Diameter

Dayton replacement condenser fan motors are used to replace damaged motors in refrigeration and air conditioning equipment and keep their performance & efficiency maintained. These condenser fans power the fan blades in air conditioning condensing units. They feature permanent split capacitors to reduce the amount of power consumed for a given load. These motors provide energy efficient performance and superior starting torque with a cooler operating temperature. Choose from a range of these condenser fan motors, available in double flat and flat shaft types.